Single-phase safety and isolating transformers

IHB-T-2


 
ihb-t2.jpg
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket. Transformer encapsulated in plastic casing, type of enclosure IP 43, non-inherently short-circuit-proof, safety class II, 50/60 Hz, ta 40°C. 
Special voltages
UPRI: 230 V
USEC: 12 - 230 V
Red Art.-No. available ex stock
Order specifications
Point on an Art.-No. to get its order specifications.
Basket
Click on an Art.-No to put it in your basket.
 
 
Output 
Article-no. for standard transformers 
Dimensions 
Weight 
Nenn-
leistung
PRI
230 V
PRI
230 V
PRI
230 V
PRI
230 V

a

b

c


Cu
kg
Ges.
kg
 
VA

SEC
12 V
SEC
24 V
SEC
42 V
SEC
230 V CEE

 



 
320
 


159
235
215
      

5,4 
 
400
 

 

159
235
215
      

1,3 
6,8 
 
500
 


159
235
215
      

1,6 
7,8 
 
 
 
Output 
Article-no. for standard transformers 
Dimensions 
Weight 
Nenn-
leistung
PRI
230 V
PRI
PRI
PRI

a

b

c


Cu
kg
Ges.
kg
 
VA

SEC
230 V Schuko
SEC
SEC
SEC

 



 
320
 

 
 
 

159
235
215
      

5,4 
 
400
 

 
 
 

159
235
215
      

1,3 
6,8 
 
500
 

 
 
 

159
235
215
      

1,6 
7,8 
 
Note:
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket. Transformer encapsulated in plastic casing, type of enclosure IP 43, non-inherently short-circuit-proof, safety class II, 50/60 Hz, ta 40°C.
Options:
* Portable transformers * Primary connection via 2 m, twin-core mains cable and moulded-on flat plug according to European norm * Secondary connection to CEE-socket * Also available matching CEE plug (please include in order if required) * Primary fuse incorporated * Test voltage primary-secondary min. 5000 V * Safety transformer < 50 V, isolating transformer > 50 V
 
Wiring Diagram

ihb-t-1.jpg
 
Dimensions

ihb-t-2.jpg
 

Column #col3

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet, sollicitudin sed, aliquet vel, quam. Pellentesque molestie laoreet tortor. Aenean quam. Pellentesque magna metus.

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet.

Nulla vitae mauris. Phasellus vel ligula quis dolor bibendum egestas. Duis a massa ut orci varius placerat. Sed leo nulla, tempor nec, commodo in, fringilla vel, nibh. Cras nibh. Pellentesque venenatis felis. Cum sociis natoque penatibus et magnis dis parturient montes.