Single-phase safety and isolating transformers

KSTF


 
kstf.jpg
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket, non-inherently short-circuit-proof. Transformer encapsulated in gum casing, resistant to shock, type of enclosure IP 54, safety class II, 50/60 Hz. 
Special voltages
UPRI: 230 V
USEC: 24 - 230 V
Red Art.-No. available ex stock
Order specifications
Point on an Art.-No. to get its order specifications.
Basket
Click on an Art.-No to put it in your basket.
 
 
Output 
Article-no. for standard transformers 
Dimensions 
Weight 
Nenn-
leistung
PRI
230 V
PRI
230 V
PRI
PRI

a

b

c


Cu
kg
Ges.
kg
 
VA

SEC
24 V CEE
SEC
230 V Schuko
SEC
SEC

 



 
630
 

 
 

250
298
295
      

2,1 
9,8 
 
1000
 

 
 

250
298
295
      

2,3 
14,7 
 
1500
 

 
 

250
298
295
      

3,6 
18,7 
 
2000
 

 
 
 

300
359
355
      

30,5 
 
Note:
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket, non-inherently short-circuit-proof. Transformer encapsulated in gum casing, resistant to shock, type of enclosure IP 54, safety class II, 50/60 Hz.
Options:
* Portable transformers * Primary connection via 2 m long, twin-core mains cable and moulded-on contour grounding plug * Up to 50 V secondary connection to a CEE-socket * From 230 V secondary connection to a contour grounding outlet (without grounding contact) * Optionally also available with several sockets (secondary) * Areas of application: - building sites - workshops * From 1000 VA incorporated inrush current limiter. * Type of enclosure IP 65 available on request * Test voltage primary-secondary min. 5000 V * Safety transformer < 50 V Isolating transformer > 50 V * as transformer for construction sites according to EN 61558, VDE 0570, part 2-23.
 
Wiring Diagram

kstk.jpg
 
Dimensions

kstf.jpg
 

Column #col3

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet, sollicitudin sed, aliquet vel, quam. Pellentesque molestie laoreet tortor. Aenean quam. Pellentesque magna metus.

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet.

Nulla vitae mauris. Phasellus vel ligula quis dolor bibendum egestas. Duis a massa ut orci varius placerat. Sed leo nulla, tempor nec, commodo in, fringilla vel, nibh. Cras nibh. Pellentesque venenatis felis. Cum sociis natoque penatibus et magnis dis parturient montes.