Single-phase power transformers

KAWN


 
kawn.jpg
Single-phase power transformer up to 16 kVA according to DIN EN 61558, VDE 0570, part 2-1 or single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. UL approved. Terminals with screwed connections, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz, dip impregnation. 
Special voltages
UPRI: 230 - 500 V
USEC: 115 - 230 V
Red Art.-No. available ex stock
Order specifications
Point on an Art.-No. to get its order specifications.
Basket
Click on an Art.-No to put it in your basket.
 
 
Output 
Article-no. for standard transformers 
Dimensions 
Weight 
Nenn-
leistung
Nenn-
leistung
PRI
230 V
PRI
400 V
PRI
500 V
PRI
230 V

a

b

c

d

e

f
Ø

Cu
kg
Ges.
kg
 
VDE Klasse B/F kVA
UL Klasse A kVA

SEC
115 V
SEC
115 V
SEC
115 V
SEC
230 V

 



 
1,6
1300,00


200
107
240
124
77
10
   

16,7 
 
2,0
1600,00


200
123
340
124
93
10
   

20,8 
 
2,5
2000,00


200
136
340
124
106
10
   

25,1 
 
3,2
2500,00


200
163
340
124
133
10
   

31,9 
 
4,0
3200,00


240
154
395
144
123
10
   

13 
37,2 
 
5,0
4000,00


240
184
395
144
153
10
   

13 
48,1 
 
6,3
5000,00


280
174
450
176
141
12
   

17 
54,7 
 
8,0
6300,00


280
189
450
176
156
12
   

19 
58,1 
 
10,0
7500,00


280
204
450
176
171
12
   

29 
82,6 
 
13,0
9500,00


280
234
450
176
201
12
   

35 
92,7 
 
16,0
11500,00


320
251
500
196
213
13
   

40 
125 
 
 
 
Output 
Article-no. for standard transformers 
Dimensions 
Weight 
Nenn-
leistung
Nenn-
leistung
PRI
400 V
PRI
500 V
PRI
PRI

a

b

c

d

e

f
Ø

Cu
kg
Ges.
kg
 
VDE Klasse B/F kVA
UL Klasse A kVA

SEC
230 V
SEC
230 V
SEC
SEC

 



 
1,6
1300,00

 
 

200
107
240
124
77
10
   

16,7 
 
2,0
1600,00

 
 

200
123
340
124
93
10
   

20,8 
 
2,5
2000,00

 
 

200
136
340
124
106
10
   

25,1 
 
3,2
2500,00

 
 

200
163
340
124
133
10
   

31,9 
 
4,0
3200,00

 
 

240
154
395
144
123
10
   

13 
37,2 
 
5,0
4000,00

 
 

240
184
395
144
153
10
   

13 
48,1 
 
6,3
5000,00

 
 

280
174
450
176
141
12
   

17 
54,7 
 
8,0
6300,00

 
 

280
189
450
176
156
12
   

19 
58,1 
 
10,0
7500,00

 
 

280
204
450
176
171
12
   

29 
82,6 
 
13,0
9500,00

 
 

280
234
450
176
201
12
   

35 
92,7 
 
16,0
11500,00

 
 

320
251
500
196
213
13
   

40 
125 
 
Note:
Single-phase power transformer up to 16 kVA according to DIN EN 61558, VDE 0570, part 2-1 or single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. UL approved. Terminals with screwed connections, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz, dip impregnation.
Options:
* Further versions on request, e.g.: - additional taps or windings - fuses - safety class II - autotransformer * Test voltage primary-secondary min. 3000 V. * Also available as autotransformer and one-coil transformer with UL authorization * Safety transformer < 50 V, isolating transformer > 50 V
 
Wiring Diagram

kawn.jpg
 
Dimensions

kawn.jpg
 

Column #col3

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet, sollicitudin sed, aliquet vel, quam. Pellentesque molestie laoreet tortor. Aenean quam. Pellentesque magna metus.

Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Nullam malesuada suscipit pede. Nullam ipsum lacus, varius vel, nonummy in, consequat ut, neque. Vivamus viverra. Duis dolor arcu, lacinia sit amet.

Nulla vitae mauris. Phasellus vel ligula quis dolor bibendum egestas. Duis a massa ut orci varius placerat. Sed leo nulla, tempor nec, commodo in, fringilla vel, nibh. Cras nibh. Pellentesque venenatis felis. Cum sociis natoque penatibus et magnis dis parturient montes.