RU-1
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 AUPRI: 230 VUSEC: 0 - 230 V
RU-2
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 2,00 - 8,00 AUPRI: 230 VUSEC: 0 - 260 V
RU-3
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 10 - 25 AUPRI: 230 VUSEC: 0 - 260 V
RU-4
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 32 AUPRI: 230 VUSEC: 0 - 260 V
RU-M-1
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 AUPRI: 230 VUSEC: 230 V
RU-M-2
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 2,00 - 8,00 AUPRI: 230 VUSEC: 230 - 260 V
RU-M-3
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 10 - 25 A UPRI: 230 V USEC: 230 - 260 V
RU-M-4
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 32 A UPRI: 230 V USEC: 230 - 260 V
DRU-1
Three-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage infinitely adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 - 3,15 AUPRI: 400 VUSEC: 0 - 450 V
DRU-2
Three-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage infinitely adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 6,3 - 23,0 AUPRI: 400 VUSEC: 0 - 450 V
DRU-M-1
Three-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 - 3,15 AUPRI: 400 VUSEC: 0 - 450 V
DRU-M-2
Three-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 6,3 - 32,0 AUPRI: 400 VUSEC: 0 - 450 V
Transformateurs toroïdaux
Nos transformateurs toroïdaux permettent le réglage en continu de la tension de zéro jusqu'à la valeur maximale. Branchés par l’intermédiaire de bornes, ils sont prêts pour la classe de protection I. Les transformateurs toroïdaux monophasés et triphasés sont également proposés avec une motorisation intégrée en fonction des modèles pour un réglage motorisé.
Transformateurs en colonne à poser
Nos transformateurs en colonne à poser permettent le réglage en continu de la tension de zéro jusqu'à la valeur maximale. Branchés par l’intermédiaire de bornes, ils sont prêts pour la classe de protection I. Ces transformateurs, tant en version monophasée qu’en version triphasée sont livrés avec une motorisation intégrée et des interrupteurs de fin de course pour leur réglage motorisé.