Three-phase power transformers
DAWN
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Connection to terminals or Cu rails, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz, dip impregnation.
P: 0,16 - 30,0 kVA UPRI: 400 V USEC: 400 V
DAWN-G
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Connection to terminals or Cu rails, sheet steel casing, prepared for safety class I, ta 40°C, type of enclosure IP 23, 50/60 Hz, dip impregnation.
P: 0,16 - 30,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DLWN
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved, horizontal mounting. Connection to terminals or Cu rails, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz.
P: 0,16 - 25,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DLWN-G
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved, sheet steel casing, horizontal mounting. Connection to terminals or Cu rails, prepared for safety class I, type of enclosure IP 23, 50/60 Hz, ta 40°C.
P: 0,16 - 25,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DAWN-GV
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Transformer in blocktype encapsulated, protection system IP 65. Connection to terminals in a connector box, safety class II, 50/60 Hz, ta 40°C.
IR: 1,0 - 15,0 AUPRI: 400 VUSEC: 400 V
Transformateurs d'adaptation triphasés
Les transformateurs d'adaptation triphasés suivant DIN EN 60076 et VDE 0532 avec sélection des tensions d’entrée et de sortie sont employés par exemple pour faire fonctionner des machines-outils, centres d’usinage et machines à équiper les circuits imprimés et adapter la tension secteur disponible à la tension d’alimentation de la machine. ISMET fournit des transformateurs d'adaptation triphasés en différentes tailles avec différents équipements et en puissance nominale jusqu'à 1MVA.
Transformateurs à gradins triphasés
Les transformateurs triphasés à gradins suivant DIN EN 61558, VDE 0570 (partie 2-13) avec enroulement commun entrée et sortie et des enroulements non séparés de manière galvanique permettent un branchement variable de l’enroulement grâce à des bornes afin de mettre à disposition plusieurs niveaux de tension avec un transformateur à gradins triphasé.
Transformateurs d’alimentation secteur triphasés
Les transformateurs d’alimentation secteur triphasés suivant VDE 0570 (partie 2-1) servent à alimenter en toute sécurité les machines, installations et appareils en 400 V et sont proposés par ISMET en puissance nominale jusqu'à 30 kVA avec ou sans boîtier. La démultiplication de 400 V à 230 V est également possible.