TS
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Terminals with screwed connection. Transformers in plastic casing, type of enclosure IP 00, safety class II, 50/60 Hz, ta 40°C.
P: 25 - 100 VAUPRI: 230 VUSEC: 12 - 24 V
TRSA
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Terminals with screwed connection, 50/60 Hz, ta 40°C (T 40/E), safety class II. Transformers in plastic casing, type of enclosure IP 54 (type TRSA).
P: 25 - 100 VAUPRI: 230 VUSEC: 12 - 230 V
WTSG
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Terminals with screwed connection, 50/60 Hz, ta 40°C (T 40/E), safety class II. Transformers in plastic casing, type of enclosure IP 43 (type WTSG).
P: 80 - 400 VAUPRI: 230 VUSEC: 11,5 - 230 V
TST
Single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary special three-pole socket (plug included in delivery), non-inherently short-circuit-proof. Transformer in sheet steel casing, type of enclosure IP 43, safety class II, 50/60 Hz, ta 40°C.
P: 63 - 250 VAUPRI: 230 VUSEC: 24 V
KSTK
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket, non-inherently short-circuit-proof. Transformer encapsulated in plastic casing, resistant to shock and temperature resistant up to 220°C, type of enclosure IP 44, safety class II, 50/60 Hz, ta 40°C.
P: 500 - 3000 VAUPRI: 230 VUSEC: 24 - 230 V
IHB-T-1
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket. Transformer encapsulated in plastic casing, type of enclosure IP 43, non-inherently short-circuit-proof, safety class II, 50/60 Hz, ta 40°C.
P: 320 - 500 VAUPRI: 230 VUSEC: 12 - 230 V
IHB-T-2
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket. Transformer encapsulated in plastic casing, type of enclosure IP 43, non-inherently short-circuit-proof, safety class II, 50/60 Hz, ta 40°C.
P: 80 - 250 VAUPRI: 230 VUSEC: 12 - 230 V
KSTF
Single-phase transformer realised as single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Primary mains cable, secondary socket, non-inherently short-circuit-proof. Transformer encapsulated in gum casing, resistant to shock, type of enclosure IP 54, safety class II, 50/60 Hz.
P: 630 - 2000 VAUPRI: 230 VUSEC: 24 - 230 V
MMGHK
Lighting transformer executed as single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 in combination with VDE 0710 part 14. Separate windings. Mains cable (without plug), primary fuse incorporated, secondary flexible connection cable. Transformer encapsulated in white plastic casing, safety class II, 50/60 Hz, ta 40°C.
P: 60 - 500 VAUPRI: 230 VUSEC: 11,5 V
Trasformatori di separazione e sicurezza monofase
I trasformatori di sicurezza monofase servono per alimentare circuiti elettrici con massimo 50 V. In questo modo si evitano tensioni di contatto elevate e quindi pericolose. I trasformatori di separazione monofase assicurano la separazione elettrica dei circuiti elettrici e pertanto dispongono di una separazione di protezione tra l'avvolgimento di entrata e di uscita. ISMET offre una grande varietà di entrambi i tipi di trasformatori in chassis o inglobati in blocchi.
Trasformatori a monte monofase
Il nostro collaudato trasformatore di risparmio a monte monofase a norma VDE 0570 (parte 2-13) è disponibile per potenze nominali di 250, 500 o 1000 VA, con pratico manico da trasporto, incorporato in chassis in plastica. I trasformatori a monte monofase convertono, a seconda del modello, la tensione di entrata a 230 V in tensione di uscita a 110 V o viceversa.
Trasformatori per illuminazione
I nostri trasformatori per illuminazione sono realizzati quali trasformatori di sicurezza monofase e hanno avvolgimenti separati. Li forniamo con cavo di rete, cavo di collegamento flessibile e fusibile montato sul primario, con nove potenze di uscita da 60 a 500 VA. I trasformatori per illuminazione ISMET sono incorporati in chassis in plastica bianca.