RU-1
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 AUPRI: 230 VUSEC: 0 - 230 V
RU-2
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 2,00 - 8,00 AUPRI: 230 VUSEC: 0 - 260 V
RU-3
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 10 - 25 AUPRI: 230 VUSEC: 0 - 260 V
RU-4
Single-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 32 AUPRI: 230 VUSEC: 0 - 260 V
RU-M-1
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 AUPRI: 230 VUSEC: 230 V
RU-M-2
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 2,00 - 8,00 AUPRI: 230 VUSEC: 230 - 260 V
RU-M-3
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 10 - 25 A UPRI: 230 V USEC: 230 - 260 V
RU-M-4
Single-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 32 A UPRI: 230 V USEC: 230 - 260 V
DRU-1
Three-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage infinitely adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 - 3,15 AUPRI: 400 VUSEC: 0 - 450 V
DRU-2
Three-phase toroidal variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with rotary switch and scale. Voltage infinitely adjustable between zero and max. value. Angle of rotation across the entire setting range approx. 330°. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 6,3 - 23,0 AUPRI: 400 VUSEC: 0 - 450 V
DRU-M-1
Three-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 1,25 - 3,15 AUPRI: 400 VUSEC: 0 - 450 V
DRU-M-2
Three-phase toroidal variable transformer according to DIN VDE 0552 designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, connection group Yn0, prepared for safety class I, 50/60 Hz, ta 40°C.
IR: 6,3 - 32,0 AUPRI: 400 VUSEC: 0 - 450 V
RSE
Single-phase column-type variable transformer according to DIN VDE 0552, executed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions. Terminal connection, 50/60 Hz, prepared for safety class I, insulation class ta 40°C.
IR: 30 - 435 AUPRI: 230 - 400 VUSEC: 230 - 400 V
DRSE
Three-phase column-type variable transformer according to DIN VDE 0552, designed as autotransformer (auto-connected winding), with attached motor drive 230 V, 50 Hz. Manipulating time approx. 27 seconds. Limit switches in min. and max. positions, connection group Yn0. Terminal connection, 50/60 Hz, prepared for safety class I, insulation class ta 40°C.
IR: 15 - 174 AUPRI: 400 VUSEC: 0 - 400 V
Trasformatori toroidali
I nostri trasformatori toroidali consentono la regolazione continua della tensione da zero al valore massimo. Sono collegati tramite morsetti e sono predisposti per la classe di protezione I. I trasformatori toroidali monofase e trifase sono offerti, a seconda del modello, anche con azionamento motorizzato integrato per la regolazione motorizzata.
Trasformatori a regolazione di tensione a colonna
I nostri trasformatori a regolazione di tensione a colonna consentono la regolazione continua della tensione da zero al valore massimo. Sono collegati tramite morsetti e sono predisposti per la classe di protezione I. Sia la versione monofase che quella trifase dei trasformatori a regolazione di tensione a colonna è fornita con azionamento motorizzato integrato e finecorsa per la regolazione motorizzata.