DAWT-G
Three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Optional primary and secondary voltage. Connection to terminals, bolts or CU rails. Transformer in sheet steel casing, color RAL 7035, type of enclosure IP 23, safety class I, 50/60 Hz, ta 40°C.
P: 40 - 125 kVAUPRI: 400 VUSEC: 230 - 400 V
DAW-G
Three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Optional primary and secondary voltage. Connection to terminals, bolts or CU rails. Transformer in sheet steel casing, color RAL 7035, type of enclosure IP 23, safety class I, 50/60 Hz, ta 40°C.
P: 160 - 1000 kVAUPRI: 400 VUSEC: 230 - 400 V
DAWT-SG
Three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Optional primary and secondary voltage. Connection to terminals, bolts or CU rails, in Sheet steel electrical cabinet IP54 prepared for safety class I, ta 40°C, 50/60 Hz, dip impregnation.
P: 40 - 125 kVAUPRI: 400 VUSEC: 230 - 400 V
DSST
Three-phase step transformer according to DIN EN 61558, VDE 0570, part 2-13. Common input and output coils. Coil without galvanic separation. Connections: Terminals with screwed connection, prepared for safety class I, 50/60 Hz, ta 40°C, dip impregnation, horizontal mounting, colour green RAL 6004.
IR: 2,75 - 35,00 AUPRI: 400 VUSEC: 120 - 400 V
DAWN
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Connection to terminals or Cu rails, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz, dip impregnation.
P: 0,16 - 30,0 kVA UPRI: 400 V USEC: 400 V
DAWN-G
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved. Connection to terminals or Cu rails, sheet steel casing, prepared for safety class I, ta 40°C, type of enclosure IP 23, 50/60 Hz, dip impregnation.
P: 0,16 - 30,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DLWN
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved, horizontal mounting. Connection to terminals or Cu rails, prepared for safety class I, ta 40°C, type of enclosure IP 00, 50/60 Hz.
P: 0,16 - 25,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DLWN-G
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 or three-phase transformer according to DIN EN 60076, VDE 0532. UL approved, sheet steel casing, horizontal mounting. Connection to terminals or Cu rails, prepared for safety class I, type of enclosure IP 23, 50/60 Hz, ta 40°C.
P: 0,16 - 25,0 kVAUPRI: 400 VUSEC: 230 - 400 V
DAWN-GV
Three-phase power transformer according to DIN EN 61558, VDE 0570, part 2-1 or three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 or three-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6. Transformer in blocktype encapsulated, protection system IP 65. Connection to terminals in a connector box, safety class II, 50/60 Hz, ta 40°C.
IR: 1,0 - 15,0 AUPRI: 400 VUSEC: 400 V
Trasformatori di adattamento trifase
Trasformatori di adattamento trifase a norma DIN EN 60076 e VDE 0532 con tensione di entrata e uscita selezionabili sono necessari ad esempio per macchine utensili, centri di lavorazione e macchine per assemblaggi e adattano la tensione di rete disponibile alla tensione di alimentazione della macchina. ISMET fornisce trasformatori di adattamento trifase con le più diverse dotazioni e dimensioni costruttive con potenze nominali fino a 1MVA.
Trasformatori trifase a commutatore
Trasformatori trifase a commutatore a norma DIN EN 61558, VDE 0570 (parte 2-13) con avvolgimenti di entrata e di uscita comuni e avvolgimenti non separati galvanicamente consentono, mediante opportuni morsetti di collegamento, prelevamenti variabili dall'avvolgimento, in modo da poter mettere a disposizione diversi livelli di tensione con un unico trasformatore trifase a commutatore.
Trasformatori per reti trifasi
I trasformatori per reti trifasi a norma VDE 0570 (parte 2-1) servono ad alimentare con tensione in maniera sicura macchine, impianti e apparecchi a 400 V e sono offerti da ISMET con potenze nominali fino a 30 kVA in varianti con e senza chassis. È possibile anche la riduzione da 400 V a 230 V.